aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2007-06-24 11:19:42 +0200
committerMark M. Hoffman <mhoffman@lightlink.com>2007-07-19 14:22:17 -0400
commitfc18d6c0479d5b6da281590a8caf166d60cc748b (patch)
tree91f3184d802e7a45223db0bb187a1e195749b62c /Documentation/hwmon
parent6b3e46458049fe556c2346a347c4540e532db288 (diff)
downloadkernel_goldelico_gta04-fc18d6c0479d5b6da281590a8caf166d60cc748b.zip
kernel_goldelico_gta04-fc18d6c0479d5b6da281590a8caf166d60cc748b.tar.gz
kernel_goldelico_gta04-fc18d6c0479d5b6da281590a8caf166d60cc748b.tar.bz2
hwmon/w83627ehf: Add support for the VID inputs
The W83627EHF and similar chips have 6 VID input pins, add support for them. The driver changes the input voltage level automatically if the current setting is not correct for the detected CPU model. Signed-off-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/w83627ehf6
1 files changed, 3 insertions, 3 deletions
diff --git a/Documentation/hwmon/w83627ehf b/Documentation/hwmon/w83627ehf
index 030fac6..ccc2bcb 100644
--- a/Documentation/hwmon/w83627ehf
+++ b/Documentation/hwmon/w83627ehf
@@ -22,9 +22,9 @@ This driver implements support for the Winbond W83627EHF, W83627EHG, and
W83627DHG super I/O chips. We will refer to them collectively as Winbond chips.
The chips implement three temperature sensors, five fan rotation
-speed sensors, ten analog voltage sensors (only nine for the 627DHG), alarms
-with beep warnings (control unimplemented), and some automatic fan regulation
-strategies (plus manual fan control mode).
+speed sensors, ten analog voltage sensors (only nine for the 627DHG), one
+VID (6 pins), alarms with beep warnings (control unimplemented), and
+some automatic fan regulation strategies (plus manual fan control mode).
Temperatures are measured in degrees Celsius and measurement resolution is 1
degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when