diff options
author | Marek Olšák <maraeo@gmail.com> | 2011-10-25 01:38:45 +0200 |
---|---|---|
committer | Dave Airlie <airlied@redhat.com> | 2011-11-20 07:53:13 +0000 |
commit | e70f224c1938af208b64b02c5cec27889fefcaec (patch) | |
tree | a247c81526e3b169158693c151efda3c2bc073e9 /include/drm | |
parent | 6991b8f2a3193397461104a27be417addb8d032b (diff) | |
download | kernel_goldelico_gta04-e70f224c1938af208b64b02c5cec27889fefcaec.zip kernel_goldelico_gta04-e70f224c1938af208b64b02c5cec27889fefcaec.tar.gz kernel_goldelico_gta04-e70f224c1938af208b64b02c5cec27889fefcaec.tar.bz2 |
drm/radeon/kms: add a CS ioctl flag not to rewrite tiling flags in the CS
This adds a new optional chunk to the CS ioctl that specifies optional flags
to the CS parser. Why this is useful is explained below. Note that some regs
no longer need the NOP relocation packet if this feature is enabled.
Tested on r300g and r600g with this flag disabled and enabled.
Assume there are two contexts sharing the same mipmapped tiled texture.
One context wants to render into the first mipmap and the other one
wants to render into the last mipmap. As you probably know, the hardware
has a MACRO_SWITCH feature, which turns off macro tiling for small mipmaps,
but that only applies to samplers.
(at least on r300-r500, though later hardware likely behaves the same)
So we want to just re-set the tiling flags before rendering (writing
packets), right? ... No. The contexts run in parallel, so they may
set the tiling flags simultaneously and then fire their command streams
also simultaneously. The last one setting the flags wins, the other one
loses.
Another problem is when one context wants to render into the first and
the last mipmap in one CS. Impossible. It must flush before changing
tiling flags and do the rendering into the smaller mipmaps in another CS.
Yet another problem is that writing copy_blit in userspace would be a mess
involving re-setting tiling flags to please the kernel, and causing races
with other contexts at the same time.
The only way out of this is to send tiling flags with each CS, ideally
with each relocation. But we already do that through the registers.
So let's just use what we have in the registers.
Signed-off-by: Marek Olšák <maraeo@gmail.com>
Signed-off-by: Dave Airlie <airlied@redhat.com>
Diffstat (limited to 'include/drm')
-rw-r--r-- | include/drm/radeon_drm.h | 4 |
1 files changed, 4 insertions, 0 deletions
diff --git a/include/drm/radeon_drm.h b/include/drm/radeon_drm.h index b65be60..be94be6 100644 --- a/include/drm/radeon_drm.h +++ b/include/drm/radeon_drm.h @@ -874,6 +874,10 @@ struct drm_radeon_gem_pwrite { #define RADEON_CHUNK_ID_RELOCS 0x01 #define RADEON_CHUNK_ID_IB 0x02 +#define RADEON_CHUNK_ID_FLAGS 0x03 + +/* The first dword of RADEON_CHUNK_ID_FLAGS is a uint32 of these flags: */ +#define RADEON_CS_KEEP_TILING_FLAGS 0x01 struct drm_radeon_cs_chunk { uint32_t chunk_id; |