aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/ds620
diff options
context:
space:
mode:
authorJames Morris <jmorris@namei.org>2011-03-08 10:55:06 +1100
committerJames Morris <jmorris@namei.org>2011-03-08 10:55:06 +1100
commit1cc26bada9f6807814806db2f0d78792eecdac71 (patch)
tree5509b5139db04af6c13db0a580c84116a4a54039 /Documentation/hwmon/ds620
parenteae61f3c829439f8f9121b5cd48a14be04df451f (diff)
parent214d93b02c4fe93638ad268613c9702a81ed9192 (diff)
downloadkernel_samsung_aries-1cc26bada9f6807814806db2f0d78792eecdac71.zip
kernel_samsung_aries-1cc26bada9f6807814806db2f0d78792eecdac71.tar.gz
kernel_samsung_aries-1cc26bada9f6807814806db2f0d78792eecdac71.tar.bz2
Merge branch 'master'; commit 'v2.6.38-rc7' into next
Diffstat (limited to 'Documentation/hwmon/ds620')
-rw-r--r--Documentation/hwmon/ds62034
1 files changed, 34 insertions, 0 deletions
diff --git a/Documentation/hwmon/ds620 b/Documentation/hwmon/ds620
new file mode 100644
index 0000000..1fbe3cd
--- /dev/null
+++ b/Documentation/hwmon/ds620
@@ -0,0 +1,34 @@
+Kernel driver ds620
+===================
+
+Supported chips:
+ * Dallas Semiconductor DS620
+ Prefix: 'ds620'
+ Datasheet: Publicly available at the Dallas Semiconductor website
+ http://www.dalsemi.com/
+
+Authors:
+ Roland Stigge <stigge@antcom.de>
+ based on ds1621.c by
+ Christian W. Zuckschwerdt <zany@triq.net>
+
+Description
+-----------
+
+The DS620 is a (one instance) digital thermometer and thermostat. It has both
+high and low temperature limits which can be user defined (i.e. programmed
+into non-volatile on-chip registers). Temperature range is -55 degree Celsius
+to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value
+returned via sysfs displays post decimal positions.
+
+The thermostat function works as follows: When configured via platform_data
+(struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin
+PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the
+output pin PO becomes active when the temperature falls below temp1_min and
+stays active until the temperature goes above temp1_max.
+
+Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO
+output pin becomes active when the temperature goes above temp1_max and stays
+active until the temperature falls below temp1_min.
+
+The PO output pin of the DS620 operates active-low.