[PATCH] ip2: use newer pci_get functions
This is one of a series of patches I plan to gradually trickle into the
tree which eliminates almost all remaining use of pci_find_* and lets me
build a pci_find_* free kernel for all but some obscure ISDN and SCSI
drivers. This is important as all pci_find_* users are not hotplug safe -
even if they are not the device being plugged.
Signed-off-by: Alan Cox <alan@redhat.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/char/ip2/ip2main.c | 10 |
1 files changed, 7 insertions, 3 deletions
diff --git a/drivers/char/ip2/ip2main.c b/drivers/char/ip2/ip2main.c index 7907ae8..331f447 100644 --- a/drivers/char/ip2/ip2main.c +++ b/drivers/char/ip2/ip2main.c @@ -436,6 +436,7 @@ cleanup_module(void) #ifdef CONFIG_PCI if (ip2config.type[i] == PCI && ip2config.pci_dev[i]) { pci_disable_device(ip2config.pci_dev[i]); + pci_dev_put(ip2config.pci_dev[i]); ip2config.pci_dev[i] = NULL; } #endif @@ -505,6 +506,7 @@ ip2_loadmain(int *iop, int *irqp, unsigned char *firmware, int firmsize) static int loaded; i2eBordStrPtr pB = NULL; int rc = -1; + static struct pci_dev *pci_dev_i = NULL; ip2trace (ITRC_NO_PORT, ITRC_INIT, ITRC_ENTER, 0 ); @@ -588,8 +590,7 @@ ip2_loadmain(int *iop, int *irqp, unsigned char *firmware, int firmsize) case PCI: #ifdef CONFIG_PCI { - struct pci_dev *pci_dev_i = NULL; - pci_dev_i = pci_find_device(PCI_VENDOR_ID_COMPUTONE, + pci_dev_i = pci_get_device(PCI_VENDOR_ID_COMPUTONE, PCI_DEVICE_ID_COMPUTONE_IP2EX, pci_dev_i); if (pci_dev_i != NULL) { unsigned int addr; @@ -600,7 +601,7 @@ ip2_loadmain(int *iop, int *irqp, unsigned char *firmware, int firmsize) break; } ip2config.type[i] = PCI; - ip2config.pci_dev[i] = pci_dev_i; + ip2config.pci_dev[i] = pci_dev_get(pci_dev_i); status = pci_read_config_dword(pci_dev_i, PCI_BASE_ADDRESS_1, &addr); if ( addr & 1 ) { @@ -641,6 +642,9 @@ ip2_loadmain(int *iop, int *irqp, unsigned char *firmware, int firmsize) break; } /* switch */ } /* for */ + if (pci_dev_i) + pci_dev_put(pci_dev_i); + for ( i = 0; i < IP2_MAX_BOARDS; ++i ) { if ( ip2config.addr[i] ) { pB = kmalloc( sizeof(i2eBordStr), GFP_KERNEL); |