healthd: Add support for HVDCP and Wipower chargers
HVDCP charger is high voltage DCP chargers. Add support to recognize it and treat them as AC power source. Also, Wipower charging is a wireless charger where the power transfer is via resonance and power control messages are exchanged over BLE. Treat Wipower as a wireless charger. CRs-Fixed: 775241 Change-Id: Id49bc31111825721ffce5a71c29f79659c5fddf0
Diffstat (limited to 'healthd')
-rw-r--r--healthd/BatteryMonitor.cpp2
1 files changed, 2 insertions, 0 deletions
diff --git a/healthd/BatteryMonitor.cpp b/healthd/BatteryMonitor.cpp
index 2f0fefe..a6725a2 100644
--- a/healthd/BatteryMonitor.cpp
+++ b/healthd/BatteryMonitor.cpp
@@ -134,7 +134,9 @@ BatteryMonitor::PowerSupplyType BatteryMonitor::readPowerSupplyType(const String
{ "USB_DCP", ANDROID_POWER_SUPPLY_TYPE_AC },
{ "USB_CDP", ANDROID_POWER_SUPPLY_TYPE_AC },
{ "USB_ACA", ANDROID_POWER_SUPPLY_TYPE_AC },
+ { "USB_HVDCP", ANDROID_POWER_SUPPLY_TYPE_AC },
{ "Wireless", ANDROID_POWER_SUPPLY_TYPE_WIRELESS },
+ { "Wipower", ANDROID_POWER_SUPPLY_TYPE_WIRELESS },
{ NULL, 0 },
};